Panels above the roof

Don Ross on a steel-frame refrigerated building where wall panels ran above the roof deck: the steel had to carry the wind load, so an additional girt was added.

Don Ross, D.W. Ross Company. 0:58.

Transcript

We had another project that we supplied a general contractor and an Amish crew down in Southern Ohio. This was an exterior envelope, steel frame, refrigerated structure. They had some other panels that went above the roof. And the structural steel wasn't there to support the wall panels for a 30 mile an hour wind load, because these panels were exposed above the roof deck. And as a consequence, an additional girt had to be added.

The other party said, oh no, our panels will work. Well, we sold the project with our Kingspan product line. And with the temperatures and with the wind loads, it wouldn't have worked. And our panels meet the industry standards of all these other suppliers. There's no magic wand that says our panel stronger than your panel. It's the same material. It's the same core.

Don Ross, President, D.W. Ross Company

More videos

All videos
1:32

When the design is wrong

Don Ross on a 34-foot freezer wall at a clear span that needed an intermediate girt, why the owner lost pallet positions when it was left out, and why D.W. Ross won't sell a job that isn't designed right.

0:27

Our name is on it

Don Ross on the company his grandfather started in 1921, the fourth generation in it now, and servicing what D.W. Ross sells.

1:02

A rectangular door in an arched opening

Dan Ross on fitting a door to an arched brick opening without cutting the brick: a rectangular door inside, corners filled in solid to form the curve, and a brick mold outside for the storm door.